MODEL CR-1461
CR-1463C is 208 Voltage, CR-1463A is 230 Voltage, CR-1463B is 460 Voltage
60 Hz.50 Hz.
Induction Motor 3Ph, 5HP, 3450 RPM 3Ph, 3.5HP, 3450 RPM
Voltage 208, 230, 460 200-220/400-440
Amperage 17.3, 15.6, 7.8 15-12/6.7
Length 19-9/16
Electrical Service to Unit No. 14 No. 14
Airflow @ 2" Opening 225 C.F.M. 5.4 CMM
Sealed Vacuum 105" H2O 245 H2O
Pump Regenerative
RECOMMENDED RELIEF VALVE SETTINGS 80" H2O 188cm H2O
Dimensions
Length 18"
Width 16-3/8"
Height 16-5/8"
Remote Control Operated 24 Volt
Shipping Weight 148 lbs.


Primary Filter - DC-1400
Filtration Cyclonic funnel primary, standpipe secondary with convenient lift off inspection lid and safety filter.
Inlet and Outlet Connections 2"
Capacity 24 Gal.
Diameter 21"
Height 62"
Radius including legs 15"
Shipping Weight 168 lbs.
Replacement Filter FD-1400


Secondary Filter - DC-500
Filtration HPB2H
Inlet and Outlet Connections 2"
Capacity 27 Qts.
Diameter 13-5/8"
Height 25-3/4"
Shipping Weight 10 lbs.
Replacement Bag HFB-4
Optional Bag Paper Bag HPB-1
* Electrical Service to unit should be installed by a licensed electrician.
NOTE: All commercial and industrial units should use 2-conducters, 18 gauge minimum for low voltage wiring (2VM-18001).
NOTE: Relief Valve should be set at a preferred setting of 80" H2O at 60 Hz. and 162 cm H2O at 50 Hz., when possible use the preferred/recommended settings above.
NOTE: The first 5 feet of metal tubing MUST be used on exhaust (SF-207).
(Upgrade to a DC-750 if fine dust control is required)